KEY FEATURES
- 1 Pair (2 Core) controlled twisted-pair construction
- Overall aluminium/polyester foil + drain wire
- 120 Ω nominal protocol-design target
- 18, 20, 22, 24 AWG Series options
- PVC, LSZH and outdoor PE jacket choices
- Exact searchable ordering code for every standard combination
Choosing the 1 Pair (2 Core) Foil Shielded CAN Bus / CANopen Bus Cable
Choose bus cable by protocol family first, because characteristic impedance and pair construction must match the bus. Then pick the screening and jacket for the route. Jacket options: PVC for general indoor routes, LSZH where low smoke and zero halogen are specified for occupied buildings, PE for outdoor routes.
- Protocol: CAN Bus / CANopen
- Impedance: 120 Ω nominal
- Cores / pairs: 1 Pair
- Conductor size: 18 AWG / 20 AWG / 22 AWG / 24 AWG
- Conductor: Solid or stranded bare-copper conductor
- Screen: Overall aluminium/polyester foil + drain wire
- Package: 305 m standard package
Related options in this range: 2 Pairs (4 Core) Foil + Braid Shielded RS-485 / BACnet MS/TP / Modbus RTU Bus Cable · 1 Pair (2 Core) Foil + Braid Shielded CAN Bus / CANopen Bus Cable · 2 Pairs (4 Core) Foil Shielded RS-485 / BACnet MS/TP / Modbus RTU Bus Cable · 1 Pair (2 Core) Foil + Braid Shielded RS-485 / BACnet MS/TP / Modbus RTU Bus Cable
Order code: 02S-CB. Send us the length, jacket and quantity for a project quotation and datasheet.
TMT 1 Pair (2 Core) Foil Shielded CAN Bus / CANopen Bus Cable Series
TMT Global 1 Pair (2 Core) Foil Shielded CAN Bus / CANopen Bus Cable is a controlled protocol-bus cable family for can and canopen machine networks and related industrial or building-automation networks. This page covers the 1 pair (2 core), foil shielded and 120 Ω nominal electrical family; the ordering table lists the exact jacket and conductor-size order codes.
KEY FEATURES
- 1 Pair (2 Core) controlled twisted-pair construction
- Overall aluminium/polyester foil + drain wire
- 120 Ω nominal protocol-design target
- 18, 20, 22, 24 AWG Series options
- PVC, LSZH and outdoor PE jacket choices
- Exact searchable ordering code for every standard combination
TYPICAL APPLICATIONS
- CAN and CANopen machine networks
- Controllers, drives, sensors and distributed I/O
- Industrial automation and mobile equipment
- Fixed installation and project-specific long-run CAN links
- Foil + braid is the primary EMC construction; foil-only versions remain controlled project options.
Technical Specification
| PARAMETER | SPECIFICATION |
| Protocol family | CAN Bus / CANopen |
| Pair / core configuration | 1 Pair (2 Core) |
| Conductor material | Bare copper |
| Conductor construction | Solid or stranded bare-copper conductor |
| Available conductor sizes | 18 AWG / 20 AWG / 22 AWG / 24 AWG |
| Pair insulation | PE / foam-skin PE, Series dependent |
| Shielding | Overall aluminium/polyester foil + drain wire |
| Outer-jacket options | PVC / LSZH / PE Outdoor |
| Cable form | Round |
| Standard colours | Violet indoor; Black outdoor |
| Characteristic impedance | 120 Ω nominal |
| Series code | 02S-CB |
| Ordering variants | Conductor size × jacket, as listed on Page C |
| Package length | 305 m standard package |
AWG / NOMINAL AREA / SERIES AVAILABILITY
| AWG | NOMINAL AREA | SERIES AVAILABILITY |
| 18 AWG | 0.823 mm² | PVC / LSZH / PE Outdoor • 305 m |
| 20 AWG | 0.519 mm² | PVC / LSZH / PE Outdoor • 305 m |
| 22 AWG | 0.326 mm² | PVC / LSZH / PE Outdoor • 305 m |
| 24 AWG | 0.205 mm² | PVC / LSZH / PE Outdoor • 305 m |
| Brand | TMT Global |
|---|---|
| AWG | 18 awg, 20 awg, 22 awg, 24 awg |
| Jacket Type | LSZH, PE Outdoor, PVC |
| Colour | Black, Violet |
| Length | 305 m |